Products
Click on an institute to get product details

all H2O products
product made by order period maturenessdocumentation, availability
and content click on 'i' for
explanation and criteria
 i 
valvalidation status,
click on 'i' for explanation
 i 
ADAlgorithm Document PSDProduct Specification Document AvData Availability CProduct Content
H2O vertical column IFE/IUP Bremen
2002 to 2012 v0.9.1:validated
v1.0: p. valid.
v1.1: validated
MPI Mainz/IUP Heidelberg
       
SRON
2003 to 2007          
HDO/H2O ratio SRON/JPL
2003 to 2005     p. validated
*): some restrictions on data use, see product details (click on institute)


SCIAMACHY H2O validation literature:
  • Dynamic Processes Governing Lower-Tropospheric HDO/H2O Ratios as Observed from Space and Ground
    Frankenberg, C., K. Yoshimura, T. Warneke, I. Aben, A. Butz, N. Deutscher, D. Griffith, F. Hase, J. Notholt, M. Schneider, H. Schrijver and T. Rockmann
    Abstract/Article: Science, 325, 1374, 2009, DOI: 10.1126/science.1173791
  • Water vapour total columns from SCIAMACHY spectra in the 2.36um window
    Schrijver, H., A.M.S. Gloudemans, C. Frankenberg and I. Aben
    Abstract/Article: Atmospheric Measurement Techniques 2, 561-571, 2009
    Method: Retrieved water vapour total vertical columns are compared with spatially and temporally collocated values from the ECMWF data
  • Comparison of monthly means of global total column water vapor retrieved from independent satellite observations
    Mieruch, S., M. Schröder, S. Noël and J. Schulz
    Abstract/Article: J. Geophys. Res., vol 115, D23310, doi:10.1029/2010JD013946, 2010
    Method: GOME/SCIAMACHY total column water vapour monthly mean measurements are compared with the passive microwave observations from SSM/I for the period of 1996 to 2005
  • Validation of two independent retrievals of SCIAMACHY water vapour columns using radiosonde data
    du Piesanie, A., A.J.M. Piters, I. Aben, H. Schrijver, P. Wang and S. Noël
    Abstract/Article: Atmospheric Measurement Techniques 6, 2925-2940
    Method: comparison with radio-sonde
  • Improved water vapour spectroscopy in the 4174–4300 cm-1 region and its impact on SCIAMACHY HDO/H2O measurements
    Scheepmaker, R. A., C. Frankenberg, A. Galli, A. Butz, H. Schrijver, N.M. Deutscher, D. Wunch, T. Warneke, S. Fally and I. Aben
    Abstract/Article: Atmospheric Measurement Techniques 6, 879-894, 2013
  • Water vapor isotopologue retrievals from high-resolution GOSAT shortwave infrared spectra
    Frankenberg, C., D. Wunch, G. Toon, C. Risi, R. Scheepmaker, J.-E. Lee, P. Wennberg and J. Worden
    Abstract/Article: Atmospheric Measurement Techniques 6, 263-274, 2013
    Method: Comparison with GOSAT, TCCON and ECMWF
  • Asian monsoon hydrometeorology from TES and SCIAMACHY water vapor isotope measurements and LMDZ simulations: Implications for speleothem climate record interpretation
    Lee, J.-E., C. Risi, I. Fung, J. Worden, R.A. Scheepmaker, B. Lintner and C. Frankenberg
    Abstract/Article: J. Geophys. Res., 117, D15112, doi:10.1029/2011JD017133, 2012
    Method: Comparison with TES and LMDZ model
  • Process-evaluation of tropospheric humidity simulated by general circulation models using water vapor isotopologues: 1. Comparison between models and observations
    Risi, C., D. Noone, J. Worden, C. Frankenberg, G. Stiller, M. Kiefer, B. Funke, K. Walker, P. Bernath, M. Schneider, D. Wunch, V. Sherlock, N. Deutscher, D. Griffith, P.O. Wennberg, K. Strong, D. Smale, E. Mahieu, S. Barthlott, F. Hase, O. Garcia, J. Notholt, T. Warneke, G. Toon, D. Sayres, S. Bony, J. Lee, D. Brown, R. Uemura and C. Sturm
    Abstract/Article: J. Geophys. Res., 117, D05303, doi:10.1029/2011JD016621, 2012

Quality criteria
Quality criteria for SCIAMACHY products

Literature overview
An overview of SCIAMACHY validation literature sorted by product

Add literature
Add validation literature

contact us
©SCIAVALIG