Products
Click on an institute to get product details

all NO2 products
product made by order period maturenessdocumentation, availability
and content click on 'i' for
explanation and criteria
 i 
valvalidation status,
click on 'i' for explanation
 i 
ADAlgorithm Document PSDProduct Specification Document AvData Availability CProduct Content
NO2 vertical column ESA
Aug 2002 to April 2012 *)  v3.01
IFE/IUP Bremen
Aug 2002 to April 2012 *)    p. valid.
KNMI/BIRA
Jan 2003 to April 2012   validated
NO2 slant column BIRA-IASB
Jan 2003 to April 2012 *)    validated
Dalhousie/SAO
Jan 2003 to April 2012      
NO2 tropospheric column IFE/IUP Bremen
Aug 2002 to end *)    validated
KNMI/BIRA
Jan 2003 to end   validated
Dalhousie/SAO
Jan 2003 to end    
MPI Mainz/IUP Heidelberg
2003 to 2011     demonst.
NO2 profile IFE/IUP Bremen
Sep 2002 to April 2012 *)   
ESA
Aug 2002 to April 2012 *)    v3.01
MPI Mainz/IUP Heidelberg
Sep 2002 to April 2012 *)     
Environment Canada
on request   p. valid.
*): some restrictions on data use, see product details (click on institute)
NO2 tropospheric column by IFE/IUP Bremen (last update: 14-3-2006)
available data August 2002 - April 2012. Data are available on request. Daily and monthly pictures are available via the DOAS web site.
point of contact Andreas Richter
algorithm description The algorithm is described in the Algorithm Document.
product details The format is plain ASCII with header of varying length. For each station, two files are created, one with daily averages and one with all individual overpasses.
Test products: NO2 total column for Ny-Alesund 2002: nya_no2_UB1_02.asc (ASCII, 9kB) nya_no2_UB1_02.all (ASCII, 0.6 MB).
validation results First validation results can be found via the DOAS web site


SCIAMACHY NO2 tropospheric column (IFE) validation literature:
  • NO2 profile retrieval using airborne multi axis UV-visible skylight absorption measurements over central Europe
    Bruns, M., S.A. Buehler, J.P. Burrows, A. Richter, A. Rozanov, P. Wang, K.P. Heue, U. Platt, I. Pundt and T. Wagner
    Abstract/Article: Atmospheric Chemistry and Physics 6, 30493058, 2006
    Product: NO2 vertical columns
    Institute: IUP- Bremen, IUP-Heidelberg
    Method: "Airborne multiaxis differential optical absorption spectrometer (AMAXDOAS)"

Quality criteria
Quality criteria for SCIAMACHY products

Literature overview
An overview of SCIAMACHY validation literature sorted by product

Add literature
Add validation literature

contact us
©SCIAVALIG